Error Code E CF
Condenser (machine room) BLDC fan motor error — no feedback signal for more than 65 seconds
Moderate
Address soon - your appliance may not work properly
Also displayed as: E CF
How to Fix
- 1
Reset the unit, then enter Test Mode 1. Check whether the condenser fan rotates. If it does, proceed to step 4.
- 2
If the fan does not rotate, manually spin the fan blade. If it feels sticky or binds, replace the condenser fan motor.
- 3
Check fan motor supply voltage at CON4 Pin 24 ~ Pin 23 in Test Mode 1. Should be 11.4–12.6 V. If absent, replace Main PCB.
- 4
Check feedback voltage at CON4 Pin 22 ~ Pin 23. If it reads 0 V or 5 V (invalid feedback), replace the motor.
- 5
Check PWM signal at CON4 Pin 21 ~ Pin 23. If it reads 0 V or 5 V (invalid PWM), replace Main PCB.
- 6
If all voltages are correct and fan rotates freely, explain to customer.